TRI-MED
INC. RESPIRATORY SOLUTIONS THAT WORK PRACTICALLY ANYWHERE !!! Toll Free Ph: 1-866-832-4549 Fax: 1-877-496-1646 E-mail : |
|
Oxygen
Cylinders ( Tanks ) and Continues Flow Regulators |
| Cylinders are Fully Hydrostatic
tested and are DOT 3AL, Canadian CTC 3AL Approved.
Here are the most common sizes. If you do not see
the
size you need, give us a call. All Cylinders are shipped Empty and are NEW. For Specifications, See Chart. These cylinders DO NOT work on the Invacare HomeFill or the Devilbiss IFill. |
![]() |
We
carry a full line of Lightweight Aluminum Cylinders from Size M2 to MM and Regulators for
just about every need. A great addition to your current System or build your own. All Cylinders are Fully tested and are DOT 3AL and or Canadian CTC 3AL Approved. Cylinders come standard with CGA870 also known as Toggle or Post Valve. The CGA540 (Threaded Connection) is used for Large Cylinders MM, M60 and Size H . |
|||||||||||
| Need a Regulator: CONTINUES FLOW REGULATOR |
| Need a Bag: CYLINDER BAGS |
| Need a Conserving Pulse Dose Regulator: PULSE DOSE REGULATORS |
Check the BOX of the Items you want,
then Click ADD TO CART at the bottom of the List to make your purchase. |
| Hear are
a few tips for Making Oxygen safer
and more reliable: A
MUST READ ! [ Oxygen Safety Home and Travel ] |
Post
* CGA870 |
Toggle
CGA870 |
Toggle
+ Gauge CGA870 |
CGA540
+ Gauge Vertical |
CGA540
ONLY |
These are the Standard Cylinder Valves used today on Oxygen Cylinders. |
![]() |
The *CGA870 Post Valve is standard. The CGA540 Valve is also available as a Special Order, Give us a call: 1-866-832-4549. | ||||
|
Use
870 Regulator |
Use
870 Regulator |
Use
870 Regulator |
Use
540 Regulator |
Use
540 Regulator |
Cylinder Specifications Chart Just Measure your Cylinder Length = H, from the BOTTOM of the Cylinder to the TOP of the Chrome Valve as shown, then match it to the chart below, find the Cylinder Size you have. NOTE: Your measurements may be slightly different, just match it to the closest size. If you have any Questions, Give us a call. |
![]() |
Cylinder Size |
Oxygen
Capacity |
Service
Pressure |
Cylinder
Length = H |
Cylinder
O.D.= D |
Cylinder
Weight |
CU.
- LITER |
PSI
- BAR |
IN.
- MM |
IN.
- MM |
LBS.
- KG |
|
M2 |
1.4
- 40 |
2216
- 153 |
9.0
- 228 |
2.5
- 63.5 |
.74
- .34 |
M4
(A) |
4
- 113 |
2216
- 153 |
12.0
- 305 |
3.2
- 81 |
1.6
- .74 |
M6
(B) |
6
- 165 |
2216
- 153 |
15.0
- 381 |
3.2
- 81 |
2.8
- 1.50 |
ML6 |
6 - 165 |
2216 - 139 |
10.68 - 245 |
4.38 - 111 |
3.4 - 1.60 |
M9
(C) |
9
- 255 |
2015
- 139 |
15.5
- 394 |
4.38
- 111 |
3.7
- 1.69 |
D |
15
- 425 |
2015
- 139 |
20.0
- 508 |
4.38
- 111 |
5.3
- 2.41 |
Jumbo
D |
22.6
- 640 |
2015
- 139 |
20.0
- 508 |
5.25
- 133 |
8.1
- 3.68 |
E |
24
- 680 |
2015
- 139 |
29.0
- 737 |
4.38
- 111 |
7.9
- 3.58 |
M60 |
61.4 - 1738 |
2216 - 153 |
23.0 - 584 |
7.25 - 184 |
21.7 - 9.86 |
MM |
122 - 3455 |
2219 - 153 |
35.75 - 908 |
8.0 - 17.55 |
38.6 - 17.55 |
H |
212 - 7842 |
2000 - 136 |
55.0 - 1120 |
9.0 - 29.0 |
120 - 83.9 |
| Here
is how to estimate
the service time a cylinder size can deliver. Example: The E Cylinder ( 680 Liters ) can deliver 11.3 Hrs. @ a flow rate of 1 LPM , ( 680 Liters / 60 Min. = 11.33 Hrs. ) or @ 4 LPM = 2.8 Hrs. To extend the Cylinder Duration, you can add an Oxygen Conserving Device that can increase cylinder Duration by a ratio or 5:1, know the E Cylinder can Deliver up to 56 Hrs. @ 1 LPM or 14.0 Hrs. @ 4 LPM. |
Oxygen Cylinder ( Tank )
Regulators CGA870 and CGA540 |
![]() |
CGA870 Oxygen Regulators for Cylinder Size M2 to E . These regulators are fitted with a brass sleeve around key parts. All regulators are laser-etched to eliminate flaking and rub off. Test method for evaluating the ignition. Sensitivity and fault tolerance of oxygen. Regulators for all medical and emergency applications. This oxygen regulator is: 4.8 " L x 2.4 " W x 1.5 " H. Flow Range : 0.12 | 0.5 | 1 | 1.5 | 2 | 3 | 4 | 6 | 8 | 10 | 15 | 25 |
| Regulator 0 to 8 LPM With Hose Barb and Contents Gauge for CGA870 Valve - SKU 20022 Rx Required |
$
35.95 |
|
| Regulator 0 to 15 LPM With Hose Barb and Contents Gauge for CGA870 Valve - SKU 20025 Rx Required |
$
39.95 |
|
| Regulator 0 to 25 LPM With Hose Barb and Contents Gauge for CGA870 Valve - SKU 20023 Rx Required |
$
45..95 |
![]() |
CGA540 Oxygen Regulators for Cylinder Size M60, MM or H. These regulators are fitted with a brass sleeve around key parts. All regulators are laser-etched to eliminate flaking and rub off. Test method for evaluating the ignition. Sensitivity and fault tolerance of oxygen. Regulators for all medical and emergency applications. Flow Range: 0.12 | 0.5 | 1 | 1.5 | 2 | 3 | 4 | 6 | 8 | 10 | 15 |
| Regulator,
for CGA540 Valve, 1/4 - 8 LPM with Hose Barb or DISS and Contents Gage - SKU 20021 Rx Required |
$
44.95 |
|
Regulator,
for CGA540 Valve, 1/4 - 15 LPM with Hose Barb or DISS and Contents Gauge - SKU 20024 Rx Required |
$
54.95 |
![]() |
Chrome 2 Wheel Deluxe Cart for E or D Size Cylinders - SKU 31001 | $
44.95 |
Check the BOX of the Items you want,
then Click
ADD TO CART at the bottom of the List to make your purchase. |
| THE
OXYGEN CYLINDER MAY BE REFILLED WITH OXYGEN BY ANY
MEDICAL/INDUSTRIAL GAS DISTRIBUTOR who uses the Compressed
Gas Association (CGA) #870 PIN-INDEXED or CGA540 UNIVERSAL
COUPLING FOR OXYGEN. Such as:
|
|
|
Check
your Local Yellow Pages under WELDING EQUIPMENT GASES Filling of Cylinders is the responsibility of the Purchaser. A Doctors Prescription or Tax ID No. is required to fill an Oxygen Cylinder, check with your local dealer. |
Have
Questions ! |
![]() |
| Need a Regulator: CONTINUES FLOW REGULATOR |
| Need a Bag: CYLINDER BAGS |
| Need a Conserving Pulse Dose Regulator: PULSE DOSE REGULATORS |
Contact Tri-Med, Inc, E-Mail:
TOLL FREE PHONE: 1-866-832-4549 - TOLL FREE FAX: 1-877-496-1646 Local Ph: 1-303-617-1050 - Local Fax: 1-303-693-2795 3552 South Olathe Street, Aurora Co. 80013 HRS: 9-4:30 - M-F Copyright 1995-2011 Tri-Med, Inc. All Rights reserved. All Sales are Final and subject to the terms and conditions as stated on this web site. |
| Today's Date: | Updated: 01-09-12 |